Mag Ic Flow Meter Wiring Diagram
These diagrams give the details of the circuitry behind the connections you need to use the mass flow meter.
Mag ic flow meter wiring diagram. The flow meter consists of metal and plastic parts all of which must be in compliance with local rules and. See video instructions here. Install the meter with enough room for future access for maintenance purposes. 6 7 exercise extreme care when withdrawing the electrode from its seat so that little or no tension is exerted on the connecting electrode wire.
The meter must be returned to the factory for electrode replacement. Two page wiring diagram below download here. Electrical connections b loosen the safety valve c and slide the pump off the brackets d. Copper wire wafer type sensors common ground plant bonding 2 grounding 4mm 10 awg 2 copper wire common ground plant bonding 2 flow supplied bonding cable grounding ring upstream flange preferably common ground plant bonding 4mm 10 awg copper wire 2 1 full bore sensors caution.
Pump unhook the pump disconnect the water circuit connections a and from the supports. 8 1 2 system diagram 27 8 1 3 mechanical installation 27 8 2 installation 28. With the wiring diagram. Vertical installation allows upward process fluid flow and is generally preferred.
Do not rely on the flange bolts or studs for. Reference manual 00809 0100 4444 rev ag october 2018 rosemount 8732em transmitter with hart protocol reference manual. 4 20 internal and external wiring guides for 4 20 as well as 1 5 vdc across a 250 ohm resistor the 0 5 vdc hookup and the pulse counter connections. As illustrated in figures 2 3 and 2 4 avoid downward flows.
Standard gaskets not provided should be installed to ensure a proper hydraulic seal. Includes single phase 2 phase supply 3 phase supply multiple installations distributed generation alternative energy and typical equipment dimensions. In other words field. Upward flow keeps the cross sectional area full regardless of flow rate.
I o wiring and specifications 3 6 i o wiring and specifications in the previous section on sourcing and sinking concepts we explained that dc i o circuits sometimes will only allow current to flow one way. Flow meter lift the fl ow meter out of the casing assembly and remove the electrical and water circuit connections. Orientation of the electrode plane is unimportant in vertical installations. The mag meter isolating liner is not intended to be used as gasket material.
This is also true for many of the field devices which have solid state transistor interfaces. Minuto 07 disassembly 7 9. Meter wiring diagrams for low voltage meter stations for in whangarei and kaipara.