Time Clock Override Switch Wiring Diagram
Channel 2 time switch on time switch off.
Time clock override switch wiring diagram. My second suggestion has more merit for such a situation imo. Use the timer output to drive a relay that in turn switches the lights via the existing contactors. The t100 series mechanical time switch has proven it can stand the test of time. My problem is the manual override does not specify manual on or off and it is a 60 minute switch timer.
Photocell and timeclock wiring diagram diagrams time clock wiring diagram electrical education of photocell and timeclock wiring diagram image source. Download time clock photocell wiring diagram pdf. Does anyone have a wiring diagram on this. Time clock switch wiring diagram 28 images emergency.
Lighting contactor wiring diagram with photocell. Motion sensor light switch wiring diagram 5a21f10e69ca9 image source. My first suggestion regarding use of a 2 way switch is perhaps not the best idea for luminaires with a long run up time such as son. I have a 2 channel time switch and photocell to control 4 3 pole contactors for lighting.
A manual override switch provides added convenience. These dependable time switches can handle electrical loads up to 40 a per pole and allow for up to 12 on off operations per day. Wire the bypass switch across the relay contacts. Momentary contact time switch for ge type low voltage latching relays transformer relay 13 pulsed time switch for low voltage signaling devices transformer 13 timed override on with warning blink or auxilary external signal before off lds ldsh 14 multi channel dry contact time switch for higher load switching using trp d trp d 15 multi.
Mechanical override switch manual override terminal single module interface pc board view manual override terminal wire run length wire gauge less than 1000 ft 305 m 24 awg to 16 awg 0 5 mm 2 to 1 5 mm over 1000 ft 305 m 18 awg to 16 awg 0 75 mm2 to 1 5 mm2 note. Channel 1 controls exterior lighting photocell on time switch off. Switches should be rated to 50 ma at 30 v or greater. The client wants a switch at the entrance to be able to turn the lights on after the time clock has already shut them off.
Time clock override switch. So wiring the override is simple enough but the customer wants the override to be. Wire strippers and miniterm tools electrician s hand tools multitesters analog and digital testers torque wrenches screwdriver and accessories hardware bolts nuts and washers firestop tork tork mechanical time switches.